Invasive Blood Pressure & Flow
 |
BP Transducers
Economical BP transducers (from Biopac). The transducer requires a mating cable (which can be supplied
with a Biopac TCI connector, or with bare wires), and replacement transducers are available
if you already have a cable.
- Operational Pressure: -50 mmHg to +300 mmHg
- Overpressure: -400 mmHg to +4000 mmHg
- Dynamic response: 100 Hz
- Transducer Dimensions: 67 mm long X 25 mm wide
- Weight: 11.5 g
- Unbalance: 50 mmHg max
- Connection ports: Male Luer X 2
- Eight hour drift: 1 mmHg after 5-minute warmup
- Isolation: =5 µA leakage at 120 VAC/60 Hz
- Operating Temperature: +15 °C to +40 °C
- Combined effects of sensitivity linearity and hysteresis: 1 mmHg (nominal)
- Output: 5 µV/mmHg (normalized to 1 V excitation)
- Sterlilization: Ethylene oxide (ETO) gas
|
 |
Harvard ISOTEC Transducers
Economical transducers for situations where the performance of non-disposable
transducer is required.
- Operating range -50 to +300 mm Hg
- Overpressure -500 to +4000 mm Hg
- Excitation up to 10 V DC/AC
- Zero drift < ±1 mmHg per 8 hours; < ±0.25 mmHg per ºC
- Temperature sensitivity < ±0.08 % per ºC
- Compliance < 0.04 mm3 per 100 mmHg
|
 |
Venous Pressure Transducer
A robust metal-encased transducer suitable for venous measurement.
- Operating range ±75 mm Hg
- Overpressure -760 to +4000 mm Hg
- Linearity ±0.15 mm Hg; long-term drift < ±0.04 mm Hg
- Dome style - easy to fill without bubbles
|
 |
Harvard Research BP Transducer
A non-disposable transducer with replaceable dome. The unit includes the capacitive
transducer, and a amplifier with LED display and high-level output.
- Output 1.0 V at 100 mmHg
- Operating range: -50 to +300 mm Hg
- Overpressure: 3000 mmHg
- Compliance 14 ul / 100 mmHg, including 300 mm of 3 mm vinyl tubing
|
 |
HSE-Harvard HAEMODYN Software
A 16-channel data acquisition system specifically designed for haemodynamic investigations.
- Uses DT301 PCI data acquisition board
- Software runs under Windows NT and 98
- Derives and displays specific haemodynamic parameters
- Easy but versatile calibration and scaling
- Data acquisition and replay modes
- Event markers and concentration information
- Data exportable to spreadsheets and other software
|
 |
Electromagnetic Flow Transducers
These flow transducers are available in perivascular form, for use with intact vessels
during surgery, or in cannulated form, for insertion into a tubing circuit.
- Available in a wide range of sizes: 0.5 - 30 mm lumen (1 - 28 mm cannulated)
- EM flow probes have excellent frequency response for pulsatile measurements
- Appropriate electronics required
|
For further details, please see Harvard's online catalog pages.
For more information and pricing details, please email us.